{"id":4051,"date":"2026-09-08T12:02:39","date_gmt":"2026-09-08T12:02:39","guid":{"rendered":"https:\/\/passionwebs.com\/elite-engines\/product\/nanni-generator-type-q2400-24ct50\/"},"modified":"2026-09-08T12:02:39","modified_gmt":"2026-09-08T12:02:39","slug":"nanni-generator-type-q2400-24ct50","status":"publish","type":"product","link":"https:\/\/passionwebs.com\/elite-engines\/product\/nanni-generator-type-q2400-24ct50\/","title":{"rendered":"Nanni Generator Type Q2400 \u2013 24CT50"},"content":{"rendered":"<h2>Description<\/h2>\n<h2 class=\"PDq2pG_selectionAnchorContainer\" data-section-id=\"1uvqtmz\" data-start=\"0\" data-end=\"68\">New Nanni Generator Type Q2400 \u2013 24CT50 Marine Generator For Sale<\/h2>\n<h3 data-section-id=\"1r1r0hj\" data-start=\"70\" data-end=\"143\">Reliable Three-Phase Marine Power for Yachts and Professional Vessels<\/h3>\n<p data-start=\"145\" data-end=\"619\">The <strong>New Nanni Q2400 24CT50 Marine Generator&nbsp;Marine Generator<\/strong> is a robust <strong data-start=\"222\" data-end=\"261\">three-phase marine diesel generator<\/strong> designed to provide stable onboard electricity for motor yachts, sailing yachts, catamarans, expedition vessels, workboats, and professional marine craft. Built around a proven Kubota diesel engine and paired with a Mecc Alte alternator, the Q2400 \u2013 24CT50 combines substantial electrical capacity, low-speed operation, and purpose-built marine engineering.<\/p>\n<p data-start=\"621\" data-end=\"1020\">The generator provides <strong data-start=\"644\" data-end=\"679\">23.3 kVA of prime running power<\/strong> and up to <strong data-start=\"690\" data-end=\"724\">24.1 kVA of limited-time power<\/strong> at 230\/400V and 50 Hz. This capacity makes it suitable for vessels operating three-phase pumps, refrigeration equipment, ventilation systems, hydraulic machinery, battery chargers, galley equipment, navigation electronics, and other demanding onboard loads.<\/p>\n<p data-start=\"1022\" data-end=\"1381\">Choosing the correct <strong data-start=\"1043\" data-end=\"1063\">marine generator<\/strong> requires more than selecting a model by its maximum output. Vessel owners, shipyards, and marine installers must also consider continuous electrical demand, starting loads, phase configuration, machinery-space dimensions, cooling requirements, exhaust routing, operating hours, and possible future equipment upgrades.<\/p>\n<p data-start=\"1383\" data-end=\"1578\">For customers seeking a capable <strong data-start=\"1415\" data-end=\"1432\">marine genset<\/strong> with reliable three-phase output, the Nanni Q2400 \u2013 24CT50 offers a practical <strong data-start=\"1511\" data-end=\"1537\">onboard power solution<\/strong> for recreational and commercial vessels.<\/p>\n<h3 data-section-id=\"14nqg0\" data-start=\"1580\" data-end=\"1634\">Marine Engineering Behind the Nanni Q2400 \u2013 24CT50<\/h3>\n<p data-start=\"1636\" data-end=\"1972\">The Nanni Q2400 platform is engineered specifically for marine use. Unlike a general-purpose industrial generator adapted for installation on a boat, this generator includes systems developed around the realities of onboard operation, including restricted ventilation, vibration, humidity, seawater exposure, and long operating periods.<\/p>\n<p data-start=\"1974\" data-end=\"2233\">The Q2400 series uses a four-cylinder, inline, four-stroke Kubota diesel engine with a displacement of approximately 2.434 litres. The engine uses mechanical regulation and operates at 1500 RPM in the 50 Hz configuration.<\/p>\n<p data-start=\"2235\" data-end=\"2518\">Its low-speed design helps reduce mechanical wear, vibration, and operating noise compared with many higher-speed generator sets. This makes the Q2400 \u2013 24CT50 suitable for vessels that require dependable electrical power without compromising long-term durability or onboard comfort.<\/p>\n<p data-start=\"2520\" data-end=\"2844\">Customers evaluating the <strong data-start=\"2545\" data-end=\"2590\">Nanni Generator Type Q2400 \u2013 24CT50 price<\/strong> should consider more than the initial purchase cost. Electrical capacity, installation compatibility, fuel consumption, maintenance accessibility, marine cooling, warranty support, and expected operating life all influence the generator\u2019s overall value.<\/p>\n<h3 data-section-id=\"12hynar\" data-start=\"2846\" data-end=\"2885\">Efficient Kubota Diesel Performance<\/h3>\n<p data-start=\"2887\" data-end=\"3229\">The Q2400 \u2013 24CT50 uses a naturally aspirated Kubota-based diesel engine designed to provide consistent performance under sustained marine loads. Diesel-powered <strong data-start=\"3048\" data-end=\"3073\">marine generator sets<\/strong> remain widely used aboard yachts and professional vessels because of their fuel efficiency, durability, and ability to support prolonged electrical demand.<\/p>\n<p data-start=\"3231\" data-end=\"3268\">The generator is designed to provide:<\/p>\n<ul data-start=\"3270\" data-end=\"3548\">\n<li data-section-id=\"9ld3f6\" data-start=\"3270\" data-end=\"3323\">Dependable electricity for essential vessel systems<\/li>\n<li data-section-id=\"1wyt8o0\" data-start=\"3324\" data-end=\"3374\">Stable operation under changing electrical loads<\/li>\n<li data-section-id=\"19gmjhh\" data-start=\"3375\" data-end=\"3415\">Efficient low-speed diesel performance<\/li>\n<li data-section-id=\"11uaqju\" data-start=\"3416\" data-end=\"3455\">Straightforward mechanical regulation<\/li>\n<li data-section-id=\"1jc4058\" data-start=\"3456\" data-end=\"3494\">Practical routine maintenance access<\/li>\n<li data-section-id=\"17ewgm5\" data-start=\"3495\" data-end=\"3548\">Reliable auxiliary power away from shore facilities<\/li>\n<\/ul>\n<p data-start=\"3550\" data-end=\"3782\">A properly sized <strong data-start=\"3567\" data-end=\"3594\">diesel marine generator<\/strong> allows vessel owners to operate pumps, refrigeration, ventilation, charging equipment, and other electrical systems without running the main propulsion engines solely for auxiliary power.<\/p>\n<p data-start=\"3784\" data-end=\"4075\">Published Nanni specifications list fuel consumption for the Q2400 \u2013 24CT50 at approximately 5.8 litres per hour. Actual consumption will vary according to electrical load, installation condition, maintenance, ambient temperature, and operating profile.<\/p>\n<h3 data-section-id=\"1wlvfu1\" data-start=\"4077\" data-end=\"4117\">Prime and Limited-Time Power Ratings<\/h3>\n<p data-start=\"4119\" data-end=\"4216\">Understanding generator ratings is essential when selecting an <strong data-start=\"4182\" data-end=\"4215\">auxiliary marine power system<\/strong>.<\/p>\n<p data-start=\"4218\" data-end=\"4246\">The Q2400 \u2013 24CT50 provides:<\/p>\n<ul data-start=\"4248\" data-end=\"4431\">\n<li data-section-id=\"1fomk37\" data-start=\"4248\" data-end=\"4282\"><strong data-start=\"4250\" data-end=\"4282\">23.3 kVA prime running power<\/strong><\/li>\n<li data-section-id=\"1dlwu4e\" data-start=\"4283\" data-end=\"4316\"><strong data-start=\"4285\" data-end=\"4316\">24.1 kVA limited-time power<\/strong><\/li>\n<li data-section-id=\"1qj58av\" data-start=\"4317\" data-end=\"4350\"><strong data-start=\"4319\" data-end=\"4350\">230\/400V three-phase output<\/strong><\/li>\n<li data-section-id=\"44msrf\" data-start=\"4351\" data-end=\"4372\"><strong data-start=\"4353\" data-end=\"4372\">50 Hz frequency<\/strong><\/li>\n<li data-section-id=\"3zt9p8\" data-start=\"4373\" data-end=\"4395\"><strong data-start=\"4375\" data-end=\"4395\">0.8 power factor<\/strong><\/li>\n<li data-section-id=\"jquth3\" data-start=\"4396\" data-end=\"4431\"><strong data-start=\"4398\" data-end=\"4431\">33.6 amps at the prime rating<\/strong><\/li>\n<\/ul>\n<p data-start=\"4433\" data-end=\"4681\">The prime rating is the more relevant figure for sustained vessel operation. The limited-time rating provides additional capacity for shorter periods and should not be treated as the continuous operating level.<\/p>\n<p data-start=\"4683\" data-end=\"4933\">A complete load assessment should consider both normal electrical consumption and the temporary starting demand created by motors, compressors, pumps, and refrigeration equipment. Starting loads can be substantially higher than normal running demand.<\/p>\n<p data-start=\"4935\" data-end=\"5198\">Selecting a generator that is too small may lead to overload, voltage instability, and premature wear. An excessively large generator may spend long periods operating under very light load. Correct sizing helps balance capacity, efficiency, and operating reserve.<\/p>\n<h3 data-section-id=\"1a4qwzb\" data-start=\"5200\" data-end=\"5264\">Three-Phase Electrical Output for Demanding Vessel Equipment<\/h3>\n<p data-start=\"5266\" data-end=\"5521\">The Nanni Q2400 \u2013 24CT50 is designed for vessels requiring dependable <strong data-start=\"5336\" data-end=\"5364\">three-phase marine power<\/strong>. Three-phase electricity is particularly useful for compatible motors and machinery because it provides balanced power distribution and efficient operation.<\/p>\n<p data-start=\"5523\" data-end=\"5578\">The generator may support compatible equipment such as:<\/p>\n<ul data-start=\"5580\" data-end=\"5871\">\n<li data-section-id=\"3bfe39\" data-start=\"5580\" data-end=\"5611\">Seawater and freshwater pumps<\/li>\n<li data-section-id=\"1eegvyj\" data-start=\"5612\" data-end=\"5647\">Refrigeration and freezer systems<\/li>\n<li data-section-id=\"ulvsbh\" data-start=\"5648\" data-end=\"5686\">Ventilation and extraction equipment<\/li>\n<li data-section-id=\"1us8lw7\" data-start=\"5687\" data-end=\"5710\">Hydraulic power units<\/li>\n<li data-section-id=\"11ssnsz\" data-start=\"5711\" data-end=\"5731\">Workshop machinery<\/li>\n<li data-section-id=\"17kttk1\" data-start=\"5732\" data-end=\"5758\">Battery-charging systems<\/li>\n<li data-section-id=\"l930x0\" data-start=\"5759\" data-end=\"5788\">Commercial galley equipment<\/li>\n<li data-section-id=\"13q3rfl\" data-start=\"5789\" data-end=\"5811\">Water-making systems<\/li>\n<li data-section-id=\"f3obp5\" data-start=\"5812\" data-end=\"5839\">Auxiliary electric motors<\/li>\n<li data-section-id=\"frhiqb\" data-start=\"5840\" data-end=\"5871\">Professional vessel equipment<\/li>\n<\/ul>\n<p data-start=\"5873\" data-end=\"6154\">The generator uses a Mecc Alte alternator operating at 1500 RPM. The Q2400 user documentation identifies the alternator used with the 24CT50 as a self-regulating, brushless unit with a four-pole design, Class H insulation, and IP23 protection.<\/p>\n<p data-start=\"6156\" data-end=\"6370\">Before installation, a qualified marine electrician should verify voltage, frequency, phase rotation, earthing arrangements, cable sizes, circuit protection, and compatibility with the vessel\u2019s distribution system.<\/p>\n<h3 data-section-id=\"sw6zne\" data-start=\"6372\" data-end=\"6414\">Stable Power for Modern Marine Systems<\/h3>\n<p data-start=\"6416\" data-end=\"6591\">Modern yachts and workboats rely on dependable electrical power for navigation, communication, safety, vessel monitoring, climate control, refrigeration, and daily operations.<\/p>\n<p data-start=\"6593\" data-end=\"6824\">The Q2400 alternator uses short-pitch windings designed to reduce harmonic content, while its self-regulating brushless design supports stable output and reduced routine alternator maintenance.<\/p>\n<p data-start=\"6826\" data-end=\"6998\">A stable <strong data-start=\"6835\" data-end=\"6869\">vessel power-generation system<\/strong> can help protect compatible onboard equipment and improve operational reliability during extended voyages or commercial service.<\/p>\n<p data-start=\"7000\" data-end=\"7316\">The generator may also support single-phase loads through a correctly engineered three-phase distribution arrangement, but load balancing should be reviewed carefully. Uneven loading across phases can affect generator performance, so the final electrical design should be completed by a competent marine electrician.<\/p>\n<h3 data-section-id=\"1rss0jh\" data-start=\"7318\" data-end=\"7360\">Marine Cooling for Sustained Operation<\/h3>\n<p data-start=\"7362\" data-end=\"7543\">Reliable cooling is critical for any <strong data-start=\"7399\" data-end=\"7430\">marine diesel generator set<\/strong>. Onboard generators normally operate inside enclosed compartments where engine heat must be removed efficiently.<\/p>\n<p data-start=\"7545\" data-end=\"7793\">The Q2400 platform is designed with marine cooling and wet-exhaust systems suitable for vessel installation. Its cooling arrangement helps maintain stable engine temperature while separating the engine\u2019s internal coolant from the raw-water circuit.<\/p>\n<p data-start=\"7795\" data-end=\"7862\">A properly maintained <strong data-start=\"7817\" data-end=\"7852\">marine generator cooling system<\/strong> supports:<\/p>\n<ul data-start=\"7864\" data-end=\"8069\">\n<li data-section-id=\"4i95tm\" data-start=\"7864\" data-end=\"7901\">Stable engine operating temperature<\/li>\n<li data-section-id=\"wxh4zk\" data-start=\"7902\" data-end=\"7945\">Reliable performance under sustained load<\/li>\n<li data-section-id=\"1wuu4af\" data-start=\"7946\" data-end=\"7988\">Protection of internal engine components<\/li>\n<li data-section-id=\"1hq7egn\" data-start=\"7989\" data-end=\"8013\">Reduced thermal stress<\/li>\n<li data-section-id=\"ugr5i1\" data-start=\"8014\" data-end=\"8037\">Longer equipment life<\/li>\n<li data-section-id=\"1ytbv01\" data-start=\"8038\" data-end=\"8069\">Consistent offshore operation<\/li>\n<\/ul>\n<p data-start=\"8071\" data-end=\"8246\">Routine inspection should include coolant condition, raw-water strainers, seawater flow, hoses, clamps, belts, impellers, heat-exchanger surfaces, and wet-exhaust connections.<\/p>\n<p data-start=\"8248\" data-end=\"8420\">Poor seawater flow, damaged impellers, blocked cooling passages, or inadequate machinery-space ventilation can cause overheating even when the generator is correctly sized.<\/p>\n<h3 data-section-id=\"h8pz74\" data-start=\"8422\" data-end=\"8463\">SI-2 Control and Generator Monitoring<\/h3>\n<p data-start=\"8465\" data-end=\"8787\">The Q2400 series uses Nanni\u2019s SI-2 control panel for generator operation and monitoring. The panel integrates information required to start, stop, and supervise the generator and connects to the engine through a dedicated extension cable or may be mounted on the soundproof enclosure.<\/p>\n<p data-start=\"8789\" data-end=\"8817\">The control system supports:<\/p>\n<ul data-start=\"8819\" data-end=\"8977\">\n<li data-section-id=\"vnj2gp\" data-start=\"8819\" data-end=\"8855\">Generator start and stop functions<\/li>\n<li data-section-id=\"1rvakir\" data-start=\"8856\" data-end=\"8885\">Engine parameter monitoring<\/li>\n<li data-section-id=\"ocb8j\" data-start=\"8886\" data-end=\"8916\">Generator status information<\/li>\n<li data-section-id=\"6et1lh\" data-start=\"8917\" data-end=\"8935\">Operating alarms<\/li>\n<li data-section-id=\"744z6g\" data-start=\"8936\" data-end=\"8956\">Fault-code display<\/li>\n<li data-section-id=\"7admi0\" data-start=\"8957\" data-end=\"8977\">System supervision<\/li>\n<\/ul>\n<p data-start=\"8979\" data-end=\"9204\">This monitoring capability helps operators identify abnormal conditions early and supports more effective troubleshooting. It does not replace preventive maintenance, but it provides useful information during daily operation.<\/p>\n<h3 data-section-id=\"ggzkhn\" data-start=\"9206\" data-end=\"9262\">Soundproof Marine Design and Installation Dimensions<\/h3>\n<p data-start=\"9264\" data-end=\"9395\">The Nanni Q2400 \u2013 24CT50 is available in a soundproof configuration designed to reduce generator noise and improve onboard comfort.<\/p>\n<p data-start=\"9397\" data-end=\"9467\">Published dimensions for the Q2400 soundproof range are approximately:<\/p>\n<ul data-start=\"9469\" data-end=\"9552\">\n<li data-section-id=\"hdh6wc\" data-start=\"9469\" data-end=\"9490\">Length: <strong data-start=\"9479\" data-end=\"9490\">1300 mm<\/strong><\/li>\n<li data-section-id=\"1u6dia\" data-start=\"9491\" data-end=\"9510\">Width: <strong data-start=\"9500\" data-end=\"9510\">600 mm<\/strong><\/li>\n<li data-section-id=\"1yll8s7\" data-start=\"9511\" data-end=\"9531\">Height: <strong data-start=\"9521\" data-end=\"9531\">695 mm<\/strong><\/li>\n<li data-section-id=\"xaetwv\" data-start=\"9532\" data-end=\"9552\">Weight: <strong data-start=\"9542\" data-end=\"9552\">436 kg<\/strong><\/li>\n<\/ul>\n<p data-start=\"9554\" data-end=\"9705\">These published dimensions and weight apply to the soundproof Q2400 configuration shown in Nanni\u2019s product guide.<\/p>\n<p data-start=\"9707\" data-end=\"9776\">A correctly installed <strong data-start=\"9729\" data-end=\"9755\">quiet marine generator<\/strong> should also include:<\/p>\n<ul data-start=\"9778\" data-end=\"9972\">\n<li data-section-id=\"1n7u8r6\" data-start=\"9778\" data-end=\"9804\">Suitable flexible mounts<\/li>\n<li data-section-id=\"j06kqo\" data-start=\"9805\" data-end=\"9842\">Correct machinery-space ventilation<\/li>\n<li data-section-id=\"1q071su\" data-start=\"9843\" data-end=\"9874\">Proper hose and cable support<\/li>\n<li data-section-id=\"1z1283b\" data-start=\"9875\" data-end=\"9909\">An engineered wet-exhaust system<\/li>\n<li data-section-id=\"etmuk9\" data-start=\"9910\" data-end=\"9940\">Adequate acoustic insulation<\/li>\n<li data-section-id=\"61z85o\" data-start=\"9941\" data-end=\"9972\">Sufficient service clearances<\/li>\n<\/ul>\n<p data-start=\"9974\" data-end=\"10204\">The enclosure alone does not determine the final onboard noise level. Hull construction, exhaust design, mounting quality, ventilation openings, and vibration transfer through the vessel structure also affect acoustic performance.<\/p>\n<h3 data-section-id=\"u3fcd2\" data-start=\"10206\" data-end=\"10260\">Marine Installation and Replacement Considerations<\/h3>\n<p data-start=\"10262\" data-end=\"10325\">The <strong data-start=\"10266\" data-end=\"10304\">Nanni Q2400 \u2013 24CT50 generator set<\/strong> may be suitable for:<\/p>\n<ul data-start=\"10327\" data-end=\"10534\">\n<li data-section-id=\"1ixkg0e\" data-start=\"10327\" data-end=\"10351\">New yacht construction<\/li>\n<li data-section-id=\"1suk4uh\" data-start=\"10352\" data-end=\"10385\">Expedition-vessel installations<\/li>\n<li data-section-id=\"1lqsvq6\" data-start=\"10386\" data-end=\"10408\">Commercial workboats<\/li>\n<li data-section-id=\"14rrwzp\" data-start=\"10409\" data-end=\"10431\">Yacht refit projects<\/li>\n<li data-section-id=\"17lc4ll\" data-start=\"10432\" data-end=\"10465\">Three-phase electrical upgrades<\/li>\n<li data-section-id=\"17e2umb\" data-start=\"10466\" data-end=\"10498\">Generator replacement projects<\/li>\n<li data-section-id=\"1p4ljq\" data-start=\"10499\" data-end=\"10534\">Professional marine power systems<\/li>\n<\/ul>\n<p data-start=\"10536\" data-end=\"10660\">When replacing an existing <strong data-start=\"10563\" data-end=\"10581\">boat generator<\/strong>, matching only the kVA rating is not enough. The installer should also verify:<\/p>\n<ul data-start=\"10662\" data-end=\"10882\">\n<li data-section-id=\"1y9sy11\" data-start=\"10662\" data-end=\"10685\">Voltage and frequency<\/li>\n<li data-section-id=\"1y2lw53\" data-start=\"10686\" data-end=\"10707\">Phase configuration<\/li>\n<li data-section-id=\"6vlnra\" data-start=\"10708\" data-end=\"10729\">Mounting dimensions<\/li>\n<li data-section-id=\"on4up\" data-start=\"10730\" data-end=\"10750\">Maintenance access<\/li>\n<li data-section-id=\"1a20cyh\" data-start=\"10751\" data-end=\"10768\">Seawater supply<\/li>\n<li data-section-id=\"fjftwg\" data-start=\"10769\" data-end=\"10792\">Exhaust back pressure<\/li>\n<li data-section-id=\"1ie24wn\" data-start=\"10793\" data-end=\"10811\">Fuel connections<\/li>\n<li data-section-id=\"1iy3v5h\" data-start=\"10812\" data-end=\"10838\">Ventilation requirements<\/li>\n<li data-section-id=\"17fizo5\" data-start=\"10839\" data-end=\"10855\">Cable capacity<\/li>\n<li data-section-id=\"e6lyp\" data-start=\"10856\" data-end=\"10882\">Generator removal access<\/li>\n<\/ul>\n<p data-start=\"10884\" data-end=\"11039\">This assessment helps ensure that the selected <strong data-start=\"10931\" data-end=\"10963\">marine generator replacement<\/strong> integrates correctly and remains serviceable throughout its operating life.<\/p>\n<h3 data-section-id=\"ibn6o9\" data-start=\"11041\" data-end=\"11085\">Applications of the Nanni Q2400 \u2013 24CT50<\/h3>\n<h4 data-start=\"11087\" data-end=\"11104\">Motor Yachts<\/h4>\n<p data-start=\"11106\" data-end=\"11274\">The generator can support compatible pumps, refrigeration equipment, ventilation systems, battery chargers, galley equipment, water makers, and onboard comfort systems.<\/p>\n<h4 data-start=\"11276\" data-end=\"11310\">Sailing Yachts and Catamarans<\/h4>\n<p data-start=\"11312\" data-end=\"11522\">Larger sailing yachts and expedition catamarans can use the generator as an <strong data-start=\"11388\" data-end=\"11422\">auxiliary onboard power system<\/strong> for navigation, communications, refrigeration, pumps, charging systems, and water-making equipment.<\/p>\n<h4 data-start=\"11524\" data-end=\"11563\">Workboats and Professional Vessels<\/h4>\n<p data-start=\"11565\" data-end=\"11766\">The Q2400 \u2013 24CT50 can serve as a reliable <strong data-start=\"11608\" data-end=\"11639\">commercial marine generator<\/strong> for hydraulic systems, pumps, ventilation equipment, workshop machinery, refrigeration, lighting, and daily operational loads.<\/p>\n<h4 data-start=\"11768\" data-end=\"11794\">Marine Refit Projects<\/h4>\n<p data-start=\"11796\" data-end=\"12004\">The generator may be considered when replacing an ageing or inefficient three-phase genset, provided its electrical output, dimensions, cooling, exhaust, and supporting systems are compatible with the vessel.<\/p>\n<h3 data-section-id=\"1dc9ny5\" data-start=\"12006\" data-end=\"12062\">Technical Specifications of the Nanni Q2400 \u2013 24CT50<\/h3>\n<div class=\"TyagGW_tableContainer\">\n<div class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\">\n<table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"12064\" data-end=\"13007\">\n<thead data-start=\"12064\" data-end=\"12091\">\n<tr data-start=\"12064\" data-end=\"12091\">\n<th class=\"last:pe-10\" data-start=\"12064\" data-end=\"12080\" data-col-size=\"sm\">Specification<\/th>\n<th class=\"last:pe-10\" data-start=\"12080\" data-end=\"12091\" data-col-size=\"md\">Details<\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"12102\" data-end=\"13007\">\n<tr data-start=\"12102\" data-end=\"12119\">\n<td data-start=\"12102\" data-end=\"12110\" data-col-size=\"sm\">Brand<\/td>\n<td data-start=\"12110\" data-end=\"12119\" data-col-size=\"md\">Nanni<\/td>\n<\/tr>\n<tr data-start=\"12120\" data-end=\"12148\">\n<td data-start=\"12120\" data-end=\"12139\" data-col-size=\"sm\">Generator Series<\/td>\n<td data-start=\"12139\" data-end=\"12148\" data-col-size=\"md\">Q2400<\/td>\n<\/tr>\n<tr data-start=\"12149\" data-end=\"12176\">\n<td data-start=\"12149\" data-end=\"12166\" data-col-size=\"sm\">Generator Type<\/td>\n<td data-start=\"12166\" data-end=\"12176\" data-col-size=\"md\">24CT50<\/td>\n<\/tr>\n<tr data-start=\"12177\" data-end=\"12225\">\n<td data-start=\"12177\" data-end=\"12198\" data-col-size=\"sm\">Generator Category<\/td>\n<td data-start=\"12198\" data-end=\"12225\" data-col-size=\"md\">Marine Diesel Generator<\/td>\n<\/tr>\n<tr data-start=\"12226\" data-end=\"12260\">\n<td data-start=\"12226\" data-end=\"12248\" data-col-size=\"sm\">Prime Running Power<\/td>\n<td data-start=\"12248\" data-end=\"12260\" data-col-size=\"md\">23.3 kVA<\/td>\n<\/tr>\n<tr data-start=\"12261\" data-end=\"12294\">\n<td data-start=\"12261\" data-end=\"12282\" data-col-size=\"sm\">Limited-Time Power<\/td>\n<td data-start=\"12282\" data-end=\"12294\" data-col-size=\"md\">24.1 kVA<\/td>\n<\/tr>\n<tr data-start=\"12295\" data-end=\"12317\">\n<td data-start=\"12295\" data-end=\"12305\" data-col-size=\"sm\">Voltage<\/td>\n<td data-start=\"12305\" data-end=\"12317\" data-col-size=\"md\">230\/400V<\/td>\n<\/tr>\n<tr data-start=\"12318\" data-end=\"12339\">\n<td data-start=\"12318\" data-end=\"12330\" data-col-size=\"sm\">Frequency<\/td>\n<td data-start=\"12330\" data-end=\"12339\" data-col-size=\"md\">50 Hz<\/td>\n<\/tr>\n<tr data-start=\"12340\" data-end=\"12382\">\n<td data-start=\"12340\" data-end=\"12367\" data-col-size=\"sm\">Electrical Configuration<\/td>\n<td data-start=\"12367\" data-end=\"12382\" data-col-size=\"md\">Three Phase<\/td>\n<\/tr>\n<tr data-start=\"12383\" data-end=\"12405\">\n<td data-start=\"12383\" data-end=\"12398\" data-col-size=\"sm\">Power Factor<\/td>\n<td data-start=\"12398\" data-end=\"12405\" data-col-size=\"md\">0.8<\/td>\n<\/tr>\n<tr data-start=\"12406\" data-end=\"12438\">\n<td data-start=\"12406\" data-end=\"12428\" data-col-size=\"sm\">Rated Prime Current<\/td>\n<td data-start=\"12428\" data-end=\"12438\" data-col-size=\"md\">33.6 A<\/td>\n<\/tr>\n<tr data-start=\"12439\" data-end=\"12469\">\n<td data-start=\"12439\" data-end=\"12457\" data-col-size=\"sm\">Operating Speed<\/td>\n<td data-start=\"12457\" data-end=\"12469\" data-col-size=\"md\">1500 RPM<\/td>\n<\/tr>\n<tr data-start=\"12470\" data-end=\"12494\">\n<td data-start=\"12470\" data-end=\"12484\" data-col-size=\"sm\">Engine Base<\/td>\n<td data-start=\"12484\" data-end=\"12494\" data-col-size=\"md\">Kubota<\/td>\n<\/tr>\n<tr data-start=\"12495\" data-end=\"12544\">\n<td data-start=\"12495\" data-end=\"12518\" data-col-size=\"sm\">Engine Configuration<\/td>\n<td data-start=\"12518\" data-end=\"12544\" data-col-size=\"md\">Four Cylinders, Inline<\/td>\n<\/tr>\n<tr data-start=\"12545\" data-end=\"12582\">\n<td data-start=\"12545\" data-end=\"12560\" data-col-size=\"sm\">Engine Cycle<\/td>\n<td data-start=\"12560\" data-end=\"12582\" data-col-size=\"md\">Four-Stroke Diesel<\/td>\n<\/tr>\n<tr data-start=\"12583\" data-end=\"12621\">\n<td data-start=\"12583\" data-end=\"12605\" data-col-size=\"sm\">Engine Displacement<\/td>\n<td data-start=\"12605\" data-end=\"12621\" data-col-size=\"md\">2.434 Litres<\/td>\n<\/tr>\n<tr data-start=\"12622\" data-end=\"12649\">\n<td data-start=\"12622\" data-end=\"12635\" data-col-size=\"sm\">Regulation<\/td>\n<td data-start=\"12635\" data-end=\"12649\" data-col-size=\"md\">Mechanical<\/td>\n<\/tr>\n<tr data-start=\"12650\" data-end=\"12682\">\n<td data-start=\"12650\" data-end=\"12669\" data-col-size=\"sm\">Alternator Brand<\/td>\n<td data-start=\"12669\" data-end=\"12682\" data-col-size=\"md\">Mecc Alte<\/td>\n<\/tr>\n<tr data-start=\"12683\" data-end=\"12731\">\n<td data-start=\"12683\" data-end=\"12701\" data-col-size=\"sm\">Alternator Type<\/td>\n<td data-start=\"12701\" data-end=\"12731\" data-col-size=\"md\">Brushless, Self-Regulating<\/td>\n<\/tr>\n<tr data-start=\"12732\" data-end=\"12764\">\n<td data-start=\"12732\" data-end=\"12756\" data-col-size=\"sm\">Alternator Protection<\/td>\n<td data-start=\"12756\" data-end=\"12764\" data-col-size=\"md\">IP23<\/td>\n<\/tr>\n<tr data-start=\"12765\" data-end=\"12795\">\n<td data-start=\"12765\" data-end=\"12784\" data-col-size=\"sm\">Insulation Class<\/td>\n<td data-start=\"12784\" data-end=\"12795\" data-col-size=\"md\">Class H<\/td>\n<\/tr>\n<tr data-start=\"12796\" data-end=\"12840\">\n<td data-start=\"12796\" data-end=\"12815\" data-col-size=\"sm\">Fuel Consumption<\/td>\n<td data-start=\"12815\" data-end=\"12840\" data-col-size=\"md\">Approximately 5.8 L\/h<\/td>\n<\/tr>\n<tr data-start=\"12841\" data-end=\"12902\">\n<td data-start=\"12841\" data-end=\"12865\" data-col-size=\"sm\">Soundproof Dimensions<\/td>\n<td data-start=\"12865\" data-end=\"12902\" data-col-size=\"md\">Approximately 1300 \u00d7 600 \u00d7 695 mm<\/td>\n<\/tr>\n<tr data-start=\"12903\" data-end=\"12947\">\n<td data-start=\"12903\" data-end=\"12923\" data-col-size=\"sm\">Soundproof Weight<\/td>\n<td data-start=\"12923\" data-end=\"12947\" data-col-size=\"md\">Approximately 436 kg<\/td>\n<\/tr>\n<tr data-start=\"12948\" data-end=\"13007\">\n<td data-start=\"12948\" data-end=\"12962\" data-col-size=\"sm\">Application<\/td>\n<td data-start=\"12962\" data-end=\"13007\" data-col-size=\"md\">Yacht, Workboat and Commercial Marine Use<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<p data-start=\"13009\" data-end=\"13235\">These specifications are based on Nanni\u2019s published Q2400 product guide and user documentation. Final ratings, equipment, dimensions, and configuration should be confirmed before ordering.<\/p>\n<h3 data-section-id=\"1pikv85\" data-start=\"13237\" data-end=\"13281\">Standard Equipment and Available Options<\/h3>\n<p data-start=\"13283\" data-end=\"13390\">The Q2400 \u2013 24CT50 is supplied as an integrated <strong data-start=\"13331\" data-end=\"13355\">marine generator set<\/strong> designed for onboard installation.<\/p>\n<p data-start=\"13392\" data-end=\"13422\">Typical equipment may include:<\/p>\n<ul data-start=\"13424\" data-end=\"13732\">\n<li data-section-id=\"fw7ehf\" data-start=\"13424\" data-end=\"13460\">Four-cylinder Kubota diesel engine<\/li>\n<li data-section-id=\"1b5h1aw\" data-start=\"13461\" data-end=\"13495\">Mecc Alte three-phase alternator<\/li>\n<li data-section-id=\"1vvs3gc\" data-start=\"13496\" data-end=\"13516\">SI-2 control panel<\/li>\n<li data-section-id=\"hubz2f\" data-start=\"13517\" data-end=\"13548\">Marine heat-exchanger cooling<\/li>\n<li data-section-id=\"pnm5im\" data-start=\"13549\" data-end=\"13579\">Raw-water circulation system<\/li>\n<li data-section-id=\"1kubwah\" data-start=\"13580\" data-end=\"13604\">Wet-exhaust components<\/li>\n<li data-section-id=\"1373nyr\" data-start=\"13605\" data-end=\"13632\">Engine protection systems<\/li>\n<li data-section-id=\"10a5g4r\" data-start=\"13633\" data-end=\"13658\">Fuel and oil filtration<\/li>\n<li data-section-id=\"1twrd4e\" data-start=\"13659\" data-end=\"13690\">Flexible mounting arrangement<\/li>\n<li data-section-id=\"18hu7zl\" data-start=\"13691\" data-end=\"13732\">Operating and maintenance documentation<\/li>\n<\/ul>\n<p data-start=\"13734\" data-end=\"13764\">Available options may include:<\/p>\n<ul data-start=\"13766\" data-end=\"13916\">\n<li data-section-id=\"1dvjaol\" data-start=\"13766\" data-end=\"13788\">Soundproof enclosure<\/li>\n<li data-section-id=\"1dix994\" data-start=\"13789\" data-end=\"13806\">Fuel pre-filter<\/li>\n<li data-section-id=\"msvxpv\" data-start=\"13807\" data-end=\"13831\">Siphon-break equipment<\/li>\n<li data-section-id=\"1c336bm\" data-start=\"13832\" data-end=\"13878\">Alternative electrical-system configurations<\/li>\n<li data-section-id=\"40fe0b\" data-start=\"13879\" data-end=\"13916\">Additional installation accessories<\/li>\n<\/ul>\n<p data-start=\"13918\" data-end=\"14047\">The final equipment package should be confirmed when ordering because vessel requirements and regional configurations may differ.<\/p>\n<h3 data-section-id=\"1rs4giq\" data-start=\"14049\" data-end=\"14105\">Genuine Nanni Generator Supply and Worldwide Support<\/h3>\n<p data-start=\"14107\" data-end=\"14336\">Customers looking for the <strong data-start=\"14133\" data-end=\"14202\">New Nanni Generator Type Q2400 \u2013 24CT50 Marine Generator for sale<\/strong> can contact our marine specialists for availability, configuration advice, technical guidance, and international delivery assistance.<\/p>\n<p data-start=\"14338\" data-end=\"14364\">We support customers with:<\/p>\n<ul data-start=\"14366\" data-end=\"14597\">\n<li data-section-id=\"1nj90c5\" data-start=\"14366\" data-end=\"14398\">Genuine Nanni generator supply<\/li>\n<li data-section-id=\"1mr12cw\" data-start=\"14399\" data-end=\"14436\">Electrical-load and sizing guidance<\/li>\n<li data-section-id=\"9osbls\" data-start=\"14437\" data-end=\"14472\">Replacement generator assessments<\/li>\n<li data-section-id=\"166goyc\" data-start=\"14473\" data-end=\"14509\">Marine application recommendations<\/li>\n<li data-section-id=\"1wy1y66\" data-start=\"14510\" data-end=\"14532\">Export documentation<\/li>\n<li data-section-id=\"as96dm\" data-start=\"14533\" data-end=\"14566\">Worldwide shipping arrangements<\/li>\n<li data-section-id=\"hm2x1e\" data-start=\"14567\" data-end=\"14597\">After-sales customer support<\/li>\n<\/ul>\n<p data-start=\"14599\" data-end=\"14837\">Whether you are completing a <strong data-start=\"14628\" data-end=\"14651\">yacht refit project<\/strong>, upgrading a commercial vessel, or installing a new <strong data-start=\"14704\" data-end=\"14740\">three-phase onboard power system<\/strong>, correct generator selection can reduce installation problems and improve long-term reliability.<\/p>\n<h3 data-section-id=\"ul2pwc\" data-start=\"14839\" data-end=\"14869\">Frequently Asked Questions<\/h3>\n<h4 data-start=\"14871\" data-end=\"14915\">What is the Nanni Q2400 \u2013 24CT50 price?<\/h4>\n<p data-start=\"14917\" data-end=\"15126\">The <strong data-start=\"14921\" data-end=\"14966\">Nanni Generator Type Q2400 \u2013 24CT50 price<\/strong> depends on configuration, optional equipment, current availability, shipping destination, and delivery requirements. Contact our team for an updated quotation.<\/p>\n<h4 data-start=\"15128\" data-end=\"15180\">How much power does the Q2400 \u2013 24CT50 produce?<\/h4>\n<p data-start=\"15182\" data-end=\"15313\">It provides <strong data-start=\"15194\" data-end=\"15229\">23.3 kVA of prime running power<\/strong> and up to <strong data-start=\"15240\" data-end=\"15274\">24.1 kVA of limited-time power<\/strong>.<\/p>\n<h4 data-start=\"15315\" data-end=\"15366\">Is the Q2400 \u2013 24CT50 a three-phase generator?<\/h4>\n<p data-start=\"15368\" data-end=\"15442\">Yes. It is a <strong data-start=\"15381\" data-end=\"15422\">230\/400V three-phase marine generator<\/strong> operating at 50 Hz.<\/p>\n<h4 data-start=\"15444\" data-end=\"15502\">Can it support pumps and commercial marine equipment?<\/h4>\n<p data-start=\"15504\" data-end=\"15655\">Yes, provided the connected equipment is electrically compatible and the combined continuous and starting loads remain within the generator\u2019s capacity.<\/p>\n<h4 data-start=\"15657\" data-end=\"15705\">Can it replace an existing yacht generator?<\/h4>\n<p data-start=\"15707\" data-end=\"15885\">Yes. It may be suitable for a <strong data-start=\"15737\" data-end=\"15769\">marine generator replacement<\/strong> when voltage, frequency, phase, output, dimensions, cooling, exhaust, and installation requirements are compatible.<\/p>\n<h4 data-start=\"15887\" data-end=\"15923\">Is a sound enclosure available?<\/h4>\n<p data-start=\"15925\" data-end=\"16079\">Yes. Nanni publishes the Q2400 \u2013 24CT50 in a soundproof configuration measuring approximately 1300 \u00d7 600 \u00d7 695 mm.<\/p>\n<h3 data-section-id=\"n5wke0\" data-start=\"16081\" data-end=\"16129\">Request a Quote for the Nanni Q2400 \u2013 24CT50<\/h3>\n<p data-start=\"16131\" data-end=\"16387\">The <strong data-start=\"16135\" data-end=\"16195\">New Nanni Generator Type Q2400 \u2013 24CT50 Marine Generator<\/strong> is a dependable choice for yacht owners, shipyards, boat builders, and professional operators requiring substantial <strong data-start=\"16312\" data-end=\"16340\">three-phase marine power<\/strong> from a proven Kubota-based generator platform.<\/p>\n<p data-start=\"16389\" data-end=\"16616\">Contact our marine generator specialists to request the latest <strong data-start=\"16452\" data-end=\"16482\">Nanni Q2400 \u2013 24CT50 price<\/strong>, confirm availability, discuss installation requirements, and receive assistance selecting the correct configuration for your vessel.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Description New Nanni Generator Type Q2400 \u2013 24CT50 Marine Generator For Sale Reliable Three-Phase Marine Power for Yachts and Professional Vessels The New Nanni Q2400 24CT50 Marine Generator&nbsp;Marine Generator is a robust three-phase marine diesel generator designed to provide stable onboard electricity for motor yachts, sailing yachts, catamarans, expedition vessels, workboats, and professional marine craft. Built around a proven Kubota diesel engine and paired with a Mecc Alte alternator, the Q2400 \u2013 24CT50 combines substantial electrical capacity, low-speed operation, and purpose-built marine engineering. The generator provides 23.3 kVA of prime running power and up to 24.1 kVA of limited-time power at 230\/400V and 50 Hz. This capacity makes it suitable for vessels operating three-phase pumps, refrigeration equipment, ventilation systems, hydraulic machinery, battery chargers, galley equipment, navigation electronics, and other demanding onboard loads. Choosing the correct marine generator requires more than selecting a model by its maximum output. Vessel owners, shipyards, and marine installers must also consider continuous electrical demand, starting loads, phase configuration, machinery-space dimensions, cooling requirements, exhaust routing, operating hours, and possible future equipment upgrades. For customers seeking a capable marine genset with reliable three-phase output, the Nanni Q2400 \u2013 24CT50 offers a practical onboard power solution for recreational and commercial vessels. Marine Engineering Behind the Nanni Q2400 \u2013 24CT50 The Nanni Q2400 platform is engineered specifically for marine use. Unlike a general-purpose industrial generator adapted for installation on a boat, this generator includes systems developed around the realities of onboard operation, including restricted ventilation, vibration, humidity, seawater exposure, and long operating periods. The Q2400 series uses a four-cylinder, inline, four-stroke Kubota diesel engine with a displacement of approximately 2.434 litres. The engine uses mechanical regulation and operates at 1500 RPM in the 50 Hz configuration. Its low-speed design helps reduce mechanical wear, vibration, and operating noise compared with many higher-speed generator sets. This makes the Q2400 \u2013 24CT50 suitable for vessels that require dependable electrical power without compromising long-term durability or onboard comfort. Customers evaluating the Nanni Generator Type Q2400 \u2013 24CT50 price should consider more than the initial purchase cost. Electrical capacity, installation compatibility, fuel consumption, maintenance accessibility, marine cooling, warranty support, and expected operating life all influence the generator\u2019s overall value. Efficient Kubota Diesel Performance The Q2400 \u2013 24CT50 uses a naturally aspirated Kubota-based diesel engine designed to provide consistent performance under sustained marine loads. Diesel-powered marine generator sets remain widely used aboard yachts and professional vessels because of their fuel efficiency, durability, and ability to support prolonged electrical demand. The generator is designed to provide: Dependable electricity for essential vessel systems Stable operation under changing electrical loads Efficient low-speed diesel performance Straightforward mechanical regulation Practical routine maintenance access Reliable auxiliary power away from shore facilities A properly sized diesel marine generator allows vessel owners to operate pumps, refrigeration, ventilation, charging equipment, and other electrical systems without running the main propulsion engines solely for auxiliary power. Published Nanni specifications list fuel consumption for the Q2400 \u2013 24CT50 at approximately 5.8 litres per hour. Actual consumption will vary according to electrical load, installation condition, maintenance, ambient temperature, and operating profile. Prime and Limited-Time Power Ratings Understanding generator ratings is essential when selecting an auxiliary marine power system. The Q2400 \u2013 24CT50 provides: 23.3 kVA prime running power 24.1 kVA limited-time power 230\/400V three-phase output 50 Hz frequency 0.8 power factor 33.6 amps at the prime rating The prime rating is the more relevant figure for sustained vessel operation. The limited-time rating provides additional capacity for shorter periods and should not be treated as the continuous operating level. A complete load assessment should consider both normal electrical consumption and the temporary starting demand created by motors, compressors, pumps, and refrigeration equipment. Starting loads can be substantially higher than normal running demand. Selecting a generator that is too small may lead to overload, voltage instability, and premature wear. An excessively large generator may spend long periods operating under very light load. Correct sizing helps balance capacity, efficiency, and operating reserve. Three-Phase Electrical Output for Demanding Vessel Equipment The Nanni Q2400 \u2013 24CT50 is designed for vessels requiring dependable three-phase marine power. Three-phase electricity is particularly useful for compatible motors and machinery because it provides balanced power distribution and efficient operation. The generator may support compatible equipment such as: Seawater and freshwater pumps Refrigeration and freezer systems Ventilation and extraction equipment Hydraulic power units Workshop machinery Battery-charging systems Commercial galley equipment Water-making systems Auxiliary electric motors Professional vessel equipment The generator uses a Mecc Alte alternator operating at 1500 RPM. The Q2400 user documentation identifies the alternator used with the 24CT50 as a self-regulating, brushless unit with a four-pole design, Class H insulation, and IP23 protection. Before installation, a qualified marine electrician should verify voltage, frequency, phase rotation, earthing arrangements, cable sizes, circuit protection, and compatibility with the vessel\u2019s distribution system. Stable Power for Modern Marine Systems Modern yachts and workboats rely on dependable electrical power for navigation, communication, safety, vessel monitoring, climate control, refrigeration, and daily operations. The Q2400 alternator uses short-pitch windings designed to reduce harmonic content, while its self-regulating brushless design supports stable output and reduced routine alternator maintenance. A stable vessel power-generation system can help protect compatible onboard equipment and improve operational reliability during extended voyages or commercial service. The generator may also support single-phase loads through a correctly engineered three-phase distribution arrangement, but load balancing should be reviewed carefully. Uneven loading across phases can affect generator performance, so the final electrical design should be completed by a competent marine electrician. Marine Cooling for Sustained Operation Reliable cooling is critical for any marine diesel generator set. Onboard generators normally operate inside enclosed compartments where engine heat must be removed efficiently. The Q2400 platform is designed with marine cooling and wet-exhaust systems suitable for vessel installation. Its cooling arrangement helps maintain stable engine temperature while separating the engine\u2019s internal coolant from the raw-water circuit. A properly maintained marine generator cooling system supports: Stable engine operating temperature Reliable performance under sustained load Protection of internal engine components<\/p>\n","protected":false},"featured_media":4050,"comment_status":"open","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_brand":[],"product_cat":[39],"product_tag":[],"class_list":["post-4051","product","type-product","status-publish","has-post-thumbnail","product_cat-nanni-marine-generators","desktop-align-left","tablet-align-left","mobile-align-left","first","instock","shipping-taxable","purchasable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/passionwebs.com\/elite-engines\/wp-json\/wp\/v2\/product\/4051","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/passionwebs.com\/elite-engines\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/passionwebs.com\/elite-engines\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/passionwebs.com\/elite-engines\/wp-json\/wp\/v2\/comments?post=4051"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/passionwebs.com\/elite-engines\/wp-json\/wp\/v2\/media\/4050"}],"wp:attachment":[{"href":"https:\/\/passionwebs.com\/elite-engines\/wp-json\/wp\/v2\/media?parent=4051"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/passionwebs.com\/elite-engines\/wp-json\/wp\/v2\/product_brand?post=4051"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/passionwebs.com\/elite-engines\/wp-json\/wp\/v2\/product_cat?post=4051"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/passionwebs.com\/elite-engines\/wp-json\/wp\/v2\/product_tag?post=4051"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}